At one time or another most scientists working in the ‘biochemical’ sciences will have to dialyze something. Dialysis is a simple technique to exchange a solute’s solution or to separate/purify differently sized molecules. Macromolecules are dialyzed by placing them in size-selective permeable tubing and subsequently equilibrating the sample with large volumes of new buffer: efficient dialysis relies upon appropriate selection of dialysis tubing and effective ‘washing’ that results from large volumes, multiple changes and full equilibration with the new buffer. I have recently been generating many fluorescent analogs of proteins and have used dialysis to remove ammonium sulfate from protein suspensions prior to labeling and to remove unincorporated succinimidyl esters of various fluorophores after labeling. For these steps I have been using Spectra/Por® dialysis tubing from Spectrum Laboratories®.
Spectra/Por® dialysis tubing is made of either regenerated cellulose (RC) or cellulose ester (CE). Cellulose has long been used for dialysis as it is uncharged and does not readily absorb solutes. Further, the selectivity of cellulose membranes is not altered greatly by many chemicals or reasonable pH and temperature ranges. Processed cellulose has crystalline regions and these regions cross-link chains to introduce structural integrity to the cellulose. Depending upon how the cellulose is processed the number of crystalline areas varies and the resultant regions between the cross-links can act like size-selective pores.
 
Many Spectra/Por® membranes are available with molecular weight cut offs (MWCO) from as little as 0.1 kDa all the way up to 300 kDa (CE membranes come in 0.1, 0.5, 1, 10, 100 and 300 kDa MWCOs, basic RC membranes come in 3.5, 6–8 and 12–14 kDa MWCOs and more expensive RC membranes have a range of MWCOs from 1–50 kDa). MWCO values are established by Spectrum® and represent the size at which a solute is 90 % retain during a test period. The small pore sizes available mean that relatively small molecules can easily be processed and I have used dialysis to buffer exchange samples of ~10 kDa with only minimal sample loss. Certain parameters such as pH may however alter MWCOs and so appropriate tubing needs to be established for a particular situation. That said, with my application using simple buffers the MWCOs have proven to be robust. Spectrum suggest that efficient separation can be achieved if the size ratio of the moieties is at least 25, this ratio is easy to achieve for buffer exchange of a protein or removal of unincorporated fluorescent dyes when labeling macromolecules. Equilibration of the membranes is relatively quick, especially for the larger pore sizes that I typically use, for instance, after labeling I can detect unincorporated dye molecules in my equilibration buffer within 2–4 hours during the first wash. This equilibration time means that 4 buffer changes can easily be performed in 24 hours.
 
Spectra/Por® is supplied in an essentially ready-to-go format, no boiling in bicarbonate buffer is needed. Spectra/Por® 1–6 merely need soaking in distilled water for 30 minutes whereas other tubing is supplied pre-hydrated and must be stored at 4 °C. One concern is that these membranes contain trace amounts of heavy metals and sulfur although Spectrum® do also produce specific cleaning solutions and supply Spectra/Por® 7 which comes with minimal contaminants. Membranes can be sterilized and also have two year shelf lives. Finally, Spectra/Por® tubing is supplied in different widths depending upon the scale of dialysis you plan.
 
For me dialysis essentially provides a ‘low maintenance’ way to perform buffer exchange or purify a sample if there is a large size differential. Other methods do exist to perform the same task including ultra-filtration units that are faster and extremely convenient. Dialysis is however, much more cost effective and so if I am not in a hurry for a sample I tend to use it. Further, dialysis does not rely on concentration of a sample and so may be more ‘gentle’ for your sample. The Spectra/Por® range of tubing definitely proves reliable, cost effective and widely applicable.
 
Peter Haggie, Ph.D.
Post-Doctoral Fellow
University of California, San Francisco
 
更多詳情請(qǐng)查閱
來(lái)源:博傲西騰醫(yī)療科技(上海)有限公司
聯(lián)系電話:021-50720328
E-mail:58837581@qq.com

用戶名: 密碼: 匿名 快速注冊(cè) 忘記密碼
評(píng)論只代表網(wǎng)友觀點(diǎn),不代表本站觀點(diǎn)。 請(qǐng)輸入驗(yàn)證碼: 8795
Copyright(C) 1998-2025 生物器材網(wǎng) 電話:021-64166852;13621656896 E-mail:info@bio-equip.com
成人欧美一区二区三区黑人免费_亚洲永久无码7777KKK_国产欧美日韩综合精品一区二区_欧美在线一区二区三区
日韩中文字幕二区| 懂色av一区二区三区蜜臀| 亚洲av免费在线观看| 人人爽人人爽人人爽学生一级| 人妻和黑人做爰猛烈电影 | 国产又色又爽无遮挡免费动态图| 亚洲精品毛片一区二区三区| 国产熟女乱子伦露脸简介| 97人妻精品一区二区三区视频| 初尝人妻滑进去了莹莹视频| 性受xxxx黑人xyx性爽免费| 成人小说亚洲一区二区三区| 扒开双腿疯狂进出爽爽爽口述漫画 | 爱如潮水3免费观看日本高清| 99久久99久久久精品色圆| 中文字幕乱码人妻一区二区三区四| 亚洲AV毛片一区二区三区| 久久国产亚洲av| 国产伦精品一区二区三区免费| 伊人久久大香线蕉AV一区| aaaaaaa片毛片免费观看| 国精产品一区一区三区| 日韩欧美国产区| 国产精品久久久久久久岛一牛影视 | 国产精品av一区二区三区| 比特币价格| 女人扒开腿免费视频| 日本少妇熟女| 亚洲一区二区三区乱码aⅴ| 国产成人一区二区三区在线播放 | 欧美日韩电影在线观看| 国产精品久久久久久久海的味av| 成人性生交大片免费7| 丰满少妇aaaaaa爰片毛片| 天天综合色一区二区三区| 精品动漫一区二区三区在线观看| 9191熟女高潮呻吟| 国产欧美精品一区| 婷婷综合久久一区二区三区| 国产又爽又黄在线看| 勃起大粗又硬湿又滑深又长|